CCKCP - S1095-P PLASTIC COATING COMPOUND, STRIPPABLE MIL-C-67991

  • MSDS: CCKCP
  • Manufacturer: SPRAYLAT CORP
  • Product Name: S1095-P PLASTIC COATING COMPOUND, STRIPPABLE MIL-C-67991
  • National Stock Number: 8030-01-181-6269
Product Identification

Product ID:S1095-P PLASTIC COATING COMPOUND, STRIPPABLE MIL-C-67991
MSDS Date:10/13/1993
FSC:8030
NIIN:01-181-6269
MSDS Number: CCKCP

Responsible Party
SPRAYLAT CORP
716 S COLUMBUS AVE
MOUNT VERNON, NY 10550-4717
US

Emergency Phone: 800-424-9300 CHEMTREC

Info Phone: 914-699-3030

Preparer: MICHAEL A SPATH

Cage: 87354

Contractor
SPRAYLAT CORPORATION
MT. VERNON, NY 10550 US

Telephone: 914-699-3030;310-559-2335

Cage: 87354

Ingredients

TITANIUM DIOXIDE PIGMENT XR 2275000

CAS: 13463-67-7

RTECS: XR2275000

Fraction By Weight: 2.0%

OSHA PEL 10 MG/M3

ACGIH TLV: 10 MG/M3


METHYL ALCOHOL (METHANOL) (SARA 313) (CERCLA) VP = 97.68

CAS: 67-56-1

RTECS: PC1400000

Fraction By Weight: 8.0%

OSHA PEL 200 MG/M3

ACGIH TLV: 200 MG/M3

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CHRONIC OVEREXPOSURE/INGESTION MAY
CAUSE CNS
DEPRESSION/HEADACHE/NAUSEA/VOMITING/DIZZINESS/UNCONSCIOUSNESS.
CHRONIC EXPOSURE MAY CAUSE TESTICULAR INJURY. MAY CAUSE LUNG
INJURY/NOSE/THROAT/UPPER RESP T RACT IRRIT. SPRAY/MIST/VAPORS MAY
IRRITEYES/NOSE THROAT/UPPER RESP TRACT/MUCOUS MEMBRANES/SKIN.
HARMFUL IF SWALLOWED.
Effects of Overexposure:SEVERE EYE IRRIT/EXTENSIVE CORNEAL INJURY.
IRRIT/DRYING/CRACKING/DERMATITIS ON CHRONIC ESPOSURE TO SKIN.

First Aid

First Aid:EYES: FLUSH W/LUKE WARM WATER 15 MIN. GET MED AID
IMMEDIATELY. SKIN: FLUSH W/LOTS OF LUKE WARM WATER. REMOVE CONTAM
CLOTHES PROMPTLY. GET IMMEDIATE MED AID. INHALATION: GET FRESH AIR.
RESTORE BREATHIN G IF REQUIRED. GET IMMEDIATE MED AID. INGEST:
RINSE MOUTH IMMED. GIVE 6-8 OZ LIQUID. NEVER GIVE ANYTHING BY MOUTH
TO UNCONSCIOUS PERSON. DON'T INDUCE VOMITING UNLESS DR ADVISES. GET
IMMED MED AID.***

Fire Fighting

Flash Point Method:TCC
Flash Point:130F,54C
Lower Limits:6.0
Upper Limits:36.0
Extinguishing Media:NAPHTHA CLASS B EXTINGUISHER, CO2, DRY CHEMICAL,
ALCOHOL FOAM DESIGNED TO EXTINGUISH NAPHTHA CLASS 1B FLAMMABLE LIQ
FIRE
Fire Fighting Procedures:EVACUATE UNPROTECTED PERSONNEL. DON'T ENTER
CONFINED SPACE W/O PERMISSION. FIGHT FIRES WEARING OSHA APPROVED
HELMET/FACE SHIELD/TURN-OUT COAT/BUNKER PANTS/*
Unusual Fire/Explosion Hazard:LIQ/VAPORS DANGEROUS FIRE HAZ/MODERATE
EXPLN HAZ WHEN EXPOSED TO HEAT/FLAME/IGNIT SOURCES. VAPORS HEAVIER
THAN AIR.MAY TRAVEL ALONG GROUND TO DISTANT IGNIT**

Accidental Release

Spill Release Procedures:STAY UPWIND UNLESS USING PROTEC EQUIP.STOP
DISCHARGE IF SAFE.REMOVE IGNIT SOURCES.VENTILATE.USE NONSPARKING
TOOLS.COVER W/INERT MAT'L TO REDUCE FUMES.KEEP OUT OF
DRAINS/SEWERS/WATERWAYS.CONTACT FIRE/P OLUTION AGENCIES.CALL SPILL
RESPONSE IFLG SPILL.
Neutralizing Agent:NA

Handling

Handling and Storage Precautions:KEEP CNTNRS COOL/DRY/AWAY FROM IGNIT
SOURCES.USE/STORE W/ADEQUATE VENTILATION.DON'T SMOKE IN STORAGE
AREA.KEEP CNTNRS TIGHTLY CLSD WHEN NOT IN USE.
Other Precautions:KEEP FROM HEAT/ELECTRICAL EQUIP/SPARKS/OPEN FLAME.
SPRINKLER FIRE PROTECTION DESIREABLE IN STORAGE AREAS.BOND/GROUND
METAL CNTNRS WHEN TRANSFERRING.AVOID INHALING VAPORS/MISTS/PERSONAL
CONTACT.EMPTY C NTNRS RETAIN RESIDUE/MAY BE HAZ.****

Exposure Controls

Respiratory Protection:USE DUST MASK OR RESPIRATOR IF CONCENTRATION
HIGH. WEAR APPROPRIATE PROPERLY FITTED NIOSH/MSHA APPROVED
RESPIRATOR DURING/AFTER APPLICATION UNLESS AIR MONITERING
DEMONSTRATED VAPOR/MIST LEVELS BELOW A PPLICABLE LIMITS.
Ventilation:AS REQUIRED TO CONTROL VAPOR/DUST/MIST CONCENTRATION. AVOID
CHRONIC BREATHING OF VAPORS.
Protective Gloves:NATURAL RUBBER/NEOPRENE/BUNA N/NITRILE.
Other Protective Equipment:APRON SHOULD BE WORN TO AVOID SKIN CONTACT.
Supplemental Safety and Health
*OR BOOTS/GLOVES/HOOD/SCBA. FIGHT FIRE FROM SAFE DISTANCE/PROTECTED
AREA. **SOURCES & FLASH BACK. KEEP WELDING/CUTTING EQUIP AWAY.
***REPORTS ASSOCIATE CHRONIC OVEREXPOSURE TO SOLVENTS W/PERMANENT
BRA IN/NS DAMAGE. INTENTIONAL MISUSE BY CONCENTRATING/INHALING MAY
BE HARMFUL/FATAL. ****DON'T FLAME CUT/WELD EMPTY DRUMS.

Chemical Properties

Boiling Pt:B.P. Text:212F,100C
Melt/Freeze Pt:M.P/F.P Text:NOT ESTIMAT
Decomp Temp:Decomp Text:NO DATA
Vapor Pres:97.68
Vapor Density:>AIR
Spec Gravity:1.07
pH:7-8.5
Viscosity:10000-40000CP
Evaporation Rate & Reference:FASTER THAN BUAC
Solubility in Water:COMPLETE
Appearance and Odor:WHITE FLUID.
Percent Volatiles by Volume:24-32
Corrosion Rate:NONE

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS. MAY CAUSE FIRE/EXPLOSION ON CONTACT.
Stability Condition to Avoid:SPARKS, OPEN FLAME, HOT SURFACES,
HEAT/IGNIT SOURCES.
Hazardous Decomposition Products:IN PRESENCE OF AIR MAY FORM OXIDES OF
CARBON & VARIOUS HYDROCARBONS.

Disposal

Waste Disposal Methods:DISPOSE IN ACCORDANCE W/APPLICABLE LOCAL, STATE,
FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.